6 Mounting
6.2 Transducers FLUXUS H721
2022-05-15, UMFLUXUS_H721V1-5EN
38
Step 1: Disassembly of the transducer mounting fixture Variofix L
Disassemble the transducer mounting fixture Variofix L.
Step 2: Fixation of the clasps to the tension straps
Select the installation instruction of the supplied clasp:
Band clamp clasp
The clasp is fixed to the tension strap (see Fig. 6.14).
Quick release clasp
The clasp is fixed to the tension strap (see Fig. 6.15).
Cut the tension strap to length (pipe circumference + at least 120 mm).
Ratchet clasp
Cut the tension strap to length (pipe circumference + at least 120 mm).
Fig. 6.13: Disassembly of the transducer mounting fixture Variofix L
1–cover
2–screw
3 nut
4–rail
5 tension strap clamp
Fig. 6.14: Band clamp clasp with tension strap Fig. 6.15: Quick release clasp with tension
strap
Caution!
The edge of the tension strap is very sharp.
Risk of injury.
Debur sharp edges.
Wear the required personal protective equipment.
Observe the applicable rules.
1
2
3
4
5
5