6.2.2.8 Fixation of PermaLok with solid band strap kit
Cut the tension strap to length (pipe circumference + at least 305 mm).
Insert the solid band through the slot of the tension strap clamp.
Line up the solid band, screw and tension strap clamp. Line up the solid band, bolt and tension strap clamp observing the
left and right side of the PermaLok, see Fig. 6.69.
Insert 25 mm of the solid band through the slot of the clip. Bend it back and press it with pliers, see Fig. 6.70.
Place the solid band around the pipe.
Position the clip as shown in Fig. 6.71.
Insert the other end of the solid band through the slot of the clip, see Fig. 6.72.
Fig. 6.69:
1 left tension strap clamp
2 right tension strap clamp
3 clip for fixation of the solid band
Fig. 6.70
Fig. 6.71 Fig. 6.72
1
2
3

Table of Contents