HF2211 Serial Server Device User Manual
http://www.iotworkshop.com - 51 -
<NTP> [Enable/Disable]
Parameter:
NTP is used for product to get and output real time. See uart fast config application
manual to fast query. Setting is valid immediately.
Enable: Enable NTP Function.
NTP Server Address: NTP Server address, domain name or IP address
NTP Server Port: port number, Default:123, Range;0~127
GMT: Time zone, default is 0, Range:-12~12.
Disable Disable NTP Function, Default value.
4.2.1.17. UART Directory
Function: Display/Set UART information directory.
Format:
Tab key query
4.2.1.18. UART/Show Instruction
Function: Display UART information function.
Format:
Query
<Show>
4.2.1.19. UART/Baudrate Instruction
Function: Display/Set UART baud rate function.
Format:
Query
<Baudrate>
Set
<Baudrate> [value]
Parameter:
Setting is valid immediately.
Value: Default: 115200. Can choose 2400, 4800, 9600, 38400, 57600, 115200,
230400, 460800
4.2.1.20. UART/Databits Instruction
Function: Display/Set UART data bits function.
Format:
Query
<Databits>
Set
<Databits> [value]
Parameter:
Setting is valid immediately.