HF2211 Serial Server Device User Manual
http://www.iotworkshop.com - 56 -
Disable: Default: Value.
4.2.1.35. UART/Edit Command
Function: Set UART parameter
Format:
Set
<Edit> [baudrate databits stopbits parity]
Parameter:
Set all UART communication parameter including baud rate, data bit, stop bit and parity.
4.2.1.36. UART/Clean Command
Function: Clear UART transmit-receive data information
Format:
Set
<Clean>
Parameter:
Clear the UART data count(Data packet/Frame/Error packet and so on) shown in
webpage.
4.2.1.37. SOCK Directory
Function: Display/Set Socket channel directory.
Format:
Tab key query
Netp and UDP are created socket channel. Itsupport maximum 5 Sockets.
4.2.1.38. SOCK/Show Command
Function: Display Socket information function.
Format:
Query
<Show>
4.2.1.39. SOCK/New Command
Function: Set new Socket information
Format:
Set
<New> [name]
Parameter:
There is a default socket created(netp). It support max 5 socket channel. Every channel
can be set as TCP/UDP/HTTP and so on. Setting is valid immediately.
Name: Socket name. Range 119 characters.
Input Sock Proto: Choose one communication method of the following.
TCP-SERVER: TCP Server Mode. It support max 5 TCP Client
connection.