EasyManuals Logo

FLIR CM85 User Manual

FLIR CM85
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #58 background imageLoading...
Page #58 background image
FLIRCM82USERMANUALDocumentIdentifier:CM82enUS_AD
22
123indicatesclockwiseorforwardrotation,whichmeansthatthepresumedphaseline1
isaheadofthepresumedphaseline2.
321indicatescounterclockwiseorreversedrotation,whichmeansthatthepresumed
phaseline2isaheadofthepresumedphaseline1.
‐‐meansthatthemeterisunabletodeterminetheresults.
LoVmeansthatuserspossiblyremovedthetestleadsbeforecompletingthetesting
procedure.Torepeatthetest,presstheOKbuttonagain.
5.9ResistanceMeasurements
Warning:Donotdodiode,resistanceorcontinuitytestsbeforeyouhaveremovedthepower
fromcapacitorsandotherdevicesundertestduringameasurement.Injurytopersonscan
occur.
1. Setthefunctionswitchtothe position.
2.
Ensurethatthemeterissettoresistancemeasurement.Ifthe orthe indicatoris
displayed,presstheMODEbuttonrepeatedlyuntilnoneoftheseindicatorsaredisplayed.
3.
InserttheblackprobeleadintothenegativeCOMterminalandtheredprobeleadinto
thepositiveΩterminal.
4.
Touchthetipsoftheprobeacrossthecircuitorcomponentundertest.
5.
Readtheresistancevalueonthedisplay.
5.10CapacitanceMeasurements
Warning:Donotdocapacitancetestsbeforeyouhaveremovedthepowerthecapacitororotherdevices
undertestduringameasurement.Injurytopersonscanoccur.
Note:Toprotecttheinternalcomponents,ifacapacitorthatisbeingtestedhasacharge,the
meterwillfirstdischargethecapandshowdiSC.Afteracompletedischargethemeterwill
conductanormaltest.diSCmayalsobedisplayediftheincorrectinputisprovided(e.g.,
measuring
voltagewhileincapacitancemode).
1. Setthefunctionswitchtothe position.
2.
InserttheblackprobeleadintothenegativeCOMterminalandtheredprobeleadinto
thepositive terminal.
3.
Touchthetipsoftheprobeacrossthepartundertest.
4.
Readthecapacitancevalueonthedisplay.
Note:Forverylargecapacitancevalues,itmaytakeseveralsecondsforthemeasurementtosettleandthe
finalreadingtostabilize.