FLIR CM85 - Electrical Specifications

FLIR CM85
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FLIRCM82USERMANUALDocumentIdentifier:CM82enUS_AD
26
Operatingaltitude:6562′(2000m)
Jawopening:1.45in.(37mm).
Pollutiondegree:2.
EMC:EN613261.
7.2Electricalspecifications
Accuracyis±(%reading+numberofdigits(dgt))at23
°
C±5
°
C(73.4
°
F±9
°
F),<80%RH.
Table7.1Voltage(TRMS)
Function Range
Accuracy(ofreading)
1
DCV
99.99V
±(0.7%+2dgt)
999.9V
ACV
0.05–99.99V ±(1.0%+5dgt)
999.9V 50–500Hz
VFD
ACV
0.05–99.99V
50–60Hz±(1%+5dgt)
999.9V
1.DCV<1000dgt,add6dgttotheaccuracy.ACV<1000dgt,add3dgttotheaccuracy.
Overloadprotection:1000V
rms
.
Inputimpedance:3.5MΩ//,<100pF.
ACconversiontype:ACcoupled,trueRMSresponding,calibratedtotheRMSvalueofasinewave
input.Accuraciesaregivenforsinewavesatfullscaleandnonsinewavesbelowhalfscale.For
nonsinewaves(50/60Hz),addthefollowingcrestfactorcorrections:
Foracrestfactorof1.4–2.0,add1.0%totheaccuracy.
Foracrestfactorof2.0–2.5,add2.5%totheaccuracy.
Foracrestfactorof2.5–3.0,add4.0%totheaccuracy.
CF:
3@460V,280A.
2@690V,420A.
AC+DCV
rms
accuracy:SameasACVspecification+DCVspecification.