FLIRCM85USERMANUALDocumentIdentifier:CM85‐en‐US_AB
28
Operatingaltitude:6562’(2000m)
Jawopening:1.77”(45mm).
Conductorsize:1.65”(42mm).
Pollutiondegree:2.
EMC:EN61326‐1.
7.2Electricalspecifications
Accuracyis±(%reading+numberofdigits(dgt))at73.4
o
F±9
o
F(23
o
C±5
o
C),<80%RH.
Table7.1Voltage(TRMS)
Function Range
Accuracy(ofreading)
1
DCV
99.99V
±(0.7%+2dgt)
999.9V
ACV
0.05–99.99V ±(1.0%+5dgt)
999.9V 50–500Hz
VFD
ACV
0.05–99.99V
50–60Hz±(1%+5dgt)
999.9V
1.DCV<1000dgt,add6dgttotheaccuracy.ACV<1000dgt,add3dgttotheaccuracy.
Overloadprotection:1000V
rms
.
Inputimpedance:3.5MΩ//,<100pF.
ACconversiontype:ACcoupled,trueRMSresponding,calibratedtotheRMSvalueofasinewave
input.Accuraciesaregivenforsinewavesatfullscaleandnon‐sinewavesbelowhalfscale.For
non‐sinewaves(50/60Hz),addthefollowingcrestfactorcorrections:
Foracrestfactorof1.4–2.0,add1.0%totheaccuracy.
Foracrestfactorof2.0–2.5,add2.5%totheaccuracy.
Fora
crestfactorof2.5–3.0,add4.0%totheaccuracy.
CF:
3@460V,460A.
2@690V,690A.
AC+DCV
rms
accuracy:SameasACVspecification+DCVspecification.