25
OPERATION (continued)
USER CONFIGURATION MODE (Advanced Options) (continued)
DAUGHTER BOARD MODULES
Output K-Factor Menu
(Requires Pulse Access or 4-20mA Daughter Board Module)
The scaled pulse output K-factor menu allows the user to enter a K-factor for the pulse output
of the meter or advance focus to the next menu.
The software will read the pulse output K-factor from the computer and display it on the top
row. The Total and Rate button presses for this menu function the same as the button
presses for the Inner Pipe Diameter Menu shown on the previous page. (See Figure 28–The
zero values shown represent an unscaled Pulse Output.)
NOTE: Pulse output values cannot exceed pulse input values. Pulse output can only be
scaled down.
When advancing focus to the next menu the
software will temporarily store (see Figure 13 and
its description for permanently saving) the Scaled
Pulse K- factor to the computer.
Figure 28
4-20mA Menu (Requires 4-20mA Daughter Board Module)
“Zero” Setting: This figure will flash for 1 second
before allowing the user to change the 4mA or
“zero” setting (see Figure 29-1). This setting will
already be configured for the minimum flowrate of
the meter this Q9 was attached to, when shipped
from the factory.
The Total and Rate button presses for this menu
function the same as the button presses for the
Inner Pipe Diameter Menu shown on the previous
page.
NOTE: Figure 29-2 shows the display when
changing “zero” or 4mA Flowrate Settings.
Figure 29-2
“Span” Setting: This figure will flash for 1
second before allowing the user to change the
20mA or “span” setting (see Figure 29-3). This
setting will already be configured for the
maximum flowrate of the meter this Q9 was
attached to when shipped from the factory.
The Total and Rate button presses for this menu
function the same as the button presses for the
Inner Pipe Diameter Menu shown on the previous
page.
Figure 29-1
Figure 29-3