6
SPECIFICATIONS
Q9 COMPUTER ELECTRONICS
Material
Transparent Amorphous Nylon
Operating
Temperature
(Standard
Display)
With following Alkaline batteries installed:
Energizer, E92 or En92 (or) Duracell, Mn2400.
-------------------------------------
+0°F to +140°F (-18°C to +60°C)
With following Lithium batteries installed:
Energizer, L92.
Temperature
With batteries removed from display.
Display
(G2S Meters
Only)
See Ambient and Fluid Temperature Limits graph on next page.
If wider operating temperature ranges are desired, reference
information on FLOMEC® Remote Kits.
Pulse
Rate
Frequency Range: 0.25 Hz – 3kHz
K-Factor
Maximum: >999,999 pulses/unit
Calibration
Correction
Minimum: -99.999%
Maximum: +99.999%
Totals
Maximum Display: 999,999 (x100)
Calibration
Yes
Power
Battery Life: 2+ years
NOTE: For externally powered daughter board modules see
specific module owner’s manual for voltage specifications.
STANDARD FEATURES INCLUDE
(2) Totalizing Registers
• (1) Factory Calibration Curve
• (1) Field Calibration Curve
• Rate of Flow Feature
• Flowrate Time Period in Day, Hour,
minutes, or Seconds