EasyManuals Logo

Fluke 43B Application Guide

Fluke 43B
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
Fluke 43
Applications Guide
Table of Contents
Chapter Title Page
Working Safely.............................................................................. 1
How to use this Manual................................................................. 2
Conventions Used.................................................................... 2
Resetting the Fluke 43B................................................................ 4
1 Basic Measurements .................................................................. 5
Introduction................................................................................... 5
Measuring Line Voltage................................................................ 6
Measuring Current ........................................................................ 7
Line Voltage and Current Simultaneously..................................... 8
Measuring Line Voltage and Current ....................................... 8
Recording Line Voltage and Current........................................ 9
Testing Continuity......................................................................... 11
Measuring Resistance .................................................................. 12
Measuring Capacitance................................................................ 13
Testing a Diode............................................................................. 14
2 Receptacle Branch Circuits ....................................................... 15
Troubleshooting Electrical Distribution Systems........................... 15
Detecting Transients (Phase to Neutral)....................................... 16
Monitoring Rapid Voltage Fluctuations......................................... 19
Measuring Voltage Harmonics...................................................... 21
Measuring Current Harmonics...................................................... 22
Measuring the Load on a Transformer.......................................... 24
Recording the Load on a Transfomer ...................................... 26
Measuring K-factor........................................................................ 29
3 Lighting Loads ............................................................................ 31
Introduction................................................................................... 31
Measuring Current Harmonics...................................................... 32
Measuring Power on Single Phase Loads.................................... 33
Measuring Surge Current.............................................................. 34

Table of Contents

Other manuals for Fluke 43B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 43B and is the answer not in the manual?

Fluke 43B Specifications

General IconGeneral
CategoryPower Quality Analyzer
InterfaceRS-232
Volts AC/DCYes
OhmsYes
ContinuityYes
Diode TestYes
CapacitanceYes
Harmonics MeasurementUp to 51st harmonic
DisplayLCD
Battery LifeApproximately 6 hours
Weight1.1 kg (2.4 lb)
Data StorageYes
Amps AC/DC0.1 to 1000 A (with clamp)
Power MeasurementW, VA, VAR, PF
Dimensions50 mm
Current Measurement RangeVia current clamp accessories (not built-in)