6270A
Operators Manual
4
Calibration and Repair Information
If calibration or repair is needed during the warranty period, contact an
authorized Fluke Calibration Service Center to arrange for repair (see Contact
Fluke Calibration). Please have the Product information ready such as the
purchase date and serial number to schedule the repair.
Specifications
General Specifications
Power Requirements .......................... 100 V ac to 240 V ac, 47 Hz to 63 Hz
Fuse .................................................... T2A 250 V ac
Max Power Consumption .................... 100 W
Operating Ambient
Temperature Range ............................ 15 °C to 35 °C
Storage Temperature .......................... -20 °C to 70 °C
Relative Humidity
Operating ...................................... <80 % to 30 °C, <70 % to 40 °C
Storage ......................................... <95 %, non-condensing. A power stabilization period of four days may
be required after extended storage at high temperature and humidity.
Vibration .............................................. MIL-T-28800E
Altitude (Operation) ............................. <2000 m
Ingress Protection ............................... IEC 60529: IP20
Safety .................................................. IEC 61010-1, Installation Category II, Pollution degree 2
Warmup Time ..................................... 15 minutes after power up or module installation, when items previously stored
within Operating Ambient Temperature Range.
Electromagnetic Compatibility (EMC)
IEC 61326-1
(Controlled EM environment) .............. IEC 61326-2-1; CISPR 11: Group 1, Class A
Group 1 equipment has intentionally generated and/or use conductively coupled
radio-frequency energy which is necessary for the internal functioning of the
equipment itself.
Class A equipment is equipment suitable for use in all establishments other than
domestic and those directly connected to a low voltage power supply network
which supplies buildings used for domestic purposes.
Emissions which exceed the levels required by CISPR 11 can occur when the
equipment is connected to a test object. The equipment may not meet the
immunity requirements of 61326-1 when test leads and/or test probes are
connected.
USA (FCC) .......................................... 47 CFR 15 subpart B, this product is considered an exempt device per clause
15.103
Korea (KCC) ....................................... Class A Equipment (Industrial Broadcasting & Communication Equipment)
This product meets requirements for industrial (Class A) electromagnetic wave
equipment and the seller or user should take notice of it. This equipment is
intended for use in business environments and not to be used in homes.
Weight
Chassis only ....................................... 13 kg (28.5 lbs)