71X Series
Calibration Manual
iv
Pressure Verification................................................................................. 31
mA Measure Verification.......................................................................... 32
Display Verification .................................................................................. 33
714 Verification (Earlier than V2.0).............................................................. 33
Thermocouple Measure Verification ........................................................ 33
Thermocouple Source Verification ........................................................... 34
Keypad Test .............................................................................................. 34
Display Verification .................................................................................. 35
714 Verification (V2.0 and Later) ................................................................. 35
Thermocouple Measure Verification ........................................................ 35
Thermocouple Source Verification ........................................................... 36
715 Verification (Earlier than V2.0).............................................................. 36
DC Voltage Source Verification ............................................................... 36
DC Current Source Verification................................................................ 38
Keypad Test .............................................................................................. 38
DC Current Measure Verification ............................................................. 38
DC Voltage Measure Verification............................................................. 39
Display Verification .................................................................................. 39
715 Verification (V2.0 and Later) ................................................................. 40
DC Voltage Source Verification ............................................................... 40
DC Current Source Verification................................................................ 41
DC Current Measure Verification ............................................................. 41
DC Voltage Measure Verification............................................................. 41
716 Verification............................................................................................. 43
mA Measure Verification.......................................................................... 43
mA Loop Power Verification.................................................................... 43
Sensor Jack Verification ........................................................................... 44
717 Verification............................................................................................. 44
Pressure Verification................................................................................. 44
mA Measure Verification.......................................................................... 46
mA Loop Power Verification.................................................................... 46
Sensor Jack Verification ........................................................................... 47
718 and 718Ex Verification........................................................................... 47
Pressure Verification................................................................................. 47
Leak Test Verification............................................................................... 48
mA Measure Verification.......................................................................... 49
mA Loop Power Verification (718 Only) ................................................. 49
Sensor Jack Verification ........................................................................... 50
Display Verification .................................................................................. 50
Calibration ......................................................................................................... 50
Preparing for Calibration............................................................................... 50
712 Calibration (V1.1 and Earlier)................................................................ 50
Millivolts Measure .................................................................................... 50
Resistance Measure................................................................................... 51
mA Measure.............................................................................................. 51
712 Calibration (V1.2 through V1.9) ............................................................ 52
712 Calibration (V2.0 and Later) .................................................................. 54
OHMS INPUT .......................................................................................... 54
OHMS OUTPUT Low Range................................................................... 54
OHMS OUTPUT High Range .................................................................. 55
713 Calibration .............................................................................................. 55
mA Measure Measure ............................................................................... 55
Pressure Measure ...................................................................................... 55
714 Calibration (Earlier than V2.0)............................................................... 57
Temperature Measure................................................................................ 57