7-1
Chapter 7
Verifying Voice over IP Service
Introduction
With the VoIP (Voice over IP) option enabled, you can
use NetTool to verify VoIP service on a link. NetTool can
track SCCP/SIP call control and measure RTP quality of
service. The VoIP Log and VoIP Monitor capture call
transactions, providing you with a step-by-step record of
major events so that you can troubleshoot problems with
VoIP service.
Note
Keeping your NetTool updated ensures that you
have access to new call control protocols as
they become available. For update instructions,
see “Updating NetTool’s Software” in Chapter 1.
Running AutoTest
To begin testing, do the following:
1. Connect NetTool inline between the network and a
PoE-powered device (see “Inline Connection” in
Chapter 2).
Caution
When operating inline with a POE-powered
device connected to NetTool, make sure that
NetTool is not plugged into the AC adapter or
into a serial device that is grounded or
damage may occur to the equipment.
2. Run AutoTest (see” Running AutoTest” in Chapter 3).