ScopeMeter
®
Test Tool
Replay, Zoom and Cursors
41
Cursors on a Mathematical Result (+ - x) Waveform
Cursor measurements on, for example, an AxB waveform give a reading in Watts if input A
measures (milli)Volts and input B measures (milli)Amperes. For other cursor measurements on,
for example, a A+B, A-B or AxB waveform no reading will be available if the input A and input B
measurement unit are different.
Cursors on Spectrum Measurements
For a cursor measurent on a spectrum:
1. From the Spectrum measurement screen, press
G to show the cursor key label.
2. Use
g f to move the cursor and observe the readings at the top of the screen.
Rise Time Measurements
For rise time measurements:
1. From Scope mode, press
G to show the cursor key labels.
2. Press 1 to highlight the Rise time icon.
3. For multiple waveforms, press 4 to select the required waveform A, B, C, D or M (if a
math function is active).
4. Press 3 to select MANUAL or AUTO (this automatically does steps 5 to 7).
5. Use
h i
to move the upper cursor to 100 % of the waveform height.
A marker is shown at 90 %.
6. Press 2 to highlight the Fall time icon.