11
General Arrangement
Electrical Specifications
220-240V, 3Wire, Single phase + Neutral + Earth, 50-60Hz.
208-220V, 3Wire, Twin Phase + Earth (Ground), 60Hz N. America. 380-415V, 5 wire, 3phase + Neutral +
Earth, 50-60Hz.
Power consumption: 8 kW
Mechanical Specifications
Sheet size: 686 x 660mm
Forming area: 646 x 620mm
Max depth of draw: 325mm
Max mould tool weight: 70Kg
Fan Power: 550W
Air Supply: 5 Bar, Dry & Filtered.
Overall width: 960mm
Length: 1932mm
Overall height: 1190mm
Overall height with cooling system: 2170mm
Weight: 260kg
Noise emissions
Noise emissions on the Formech 686PT are less than 70dB(A).
Machine storage
The Formech 686PT must be stored in a dry environment. If the machine is not used for a long period of
time, run the pump periodically (once a month).
Machine transportation, lifting and moving
The Formech 686PT is prepared for transportation with the heater Locked forwards and the heater guard,
counterweights and accessories individually packed. All assemblies are supplied on a pallet or pallet crate
with the load centre of gravity approximately central.
Before lifting, remove all separate assemblies and leave the heater fixed in its position until located at its
operating site. Remove packaging where it assists with lifting and moving.
The machine may be lifted from either side taking particular care to avoid damage to the front clamping
frame and panels.
ENSURE THAT LOCAL LIFTING AND HANDLING PROCEDURES ARE APPLIED AND MONITORED BY
A PERSON RESPONSIBLE FOR HEALTH AND SAFETY.