MAINTENANCE
Troubleshooting
48
Run On
Won’t stop pump
Green
Motor Frequency
Pressure sensor
placement and setting
Tank pre-charge
pressure
Impeller damage
Leaky system
Sized improperly (pump
can’t build enough
head)
Check frequency at low flows, pressure setting may be
too close to pump max head
Verify precharge at 70% if tank size is larger than
minimum, increase precharge (up to 85%)
Verify that the system will build and hold pressure
Enable bump and/or aggressive bump
Increase minimum frequency
Runs But Trips Flashing Red
Check fault code and
see corrective action
Proceed to fault code description and remedy
Low Pressure
Green
Motor Frequency
Pressure sensor setting,
pump rotation, pump
sizing
High temperature
Adjust pressure sensor, check pump rotation
Check frequency at max flow, check max pressure
High ambient and/or drive temperature will cause drive
to foldback power and run with reduced performance
High Pressure
Green
Motor Frequency
Pressure sensor setting
Shorted sensor wire
Adjust pressure sensor
Remove sensor wire at Pressure Input Board, if drive
stops running, wire may be shorted
Remove sensor wire at Pressure Input Board, if drive
continues to run, replace Pressure Input Board
Remove sensor wire at new Pressure Input Board, if drive
continues to run, replace drive
Verify condition of sensor wire and repair or replace if
necessary
Audible Noise
Green
Motor Frequency
Fan, hydraulic, plumbing
For excessive fan noise, replace fan
If fan noise is normal, drive will need to be relocated to a
more remote area
If hydraulic, try raising or lowering depth of pump
Pressure tank location should be at entrance of water line
into house
No Display None
Display board cable
disconnected or loose
Verify cable connection between main control board and
display board
Cannot Connect to
Drive Wi-Fi
FE Connect Light
On Solid
Attempting to connect
to incorrect drive
Out of Wi-Fi range of
drive
Ensure the Wi-Fi SSID (hotspot name) you are
connecting to matches the drive you wish to connect to
Wi-Fi range is 100 feet line-of-site, must be closer to
drive if walls or floors are between you and the drive
Wi-Fi module not responding, cycle power to drive
Cycle Wi-Fi radio on mobile device, refresh Wi-Fi
connection list
FE Connect Light
Off
Wi-Fi timeout expired
If more than fifteen (15) minutes since last power cycle,
cycle power to drive
If more than one (1) hour since last disconnection from
Wi-Fi, cycle power to drive
RFI-EMI
Interference
Green
Motor Frequency
Poor grounding
Wire routing
Adhere to grounding and wire routing recommendations
An additional external filter may be needed.
System Regulates
but displays 199P
Green
199P
The pressure in the
system is 199 psi or
higher
The max pressure the display can show is 199psi. Use the
pressure gauge or Wi-Fi / FE-Connect app to view the
system pressure.
Condition Display Possible Cause Corrective Action