79
VFD-19 Speed A
Speed A
19) 30Hz
Min: PRIMARY-10
Max: PRIMARY-7
Default: 30.00Hz
Presetfrequency‐AbydigitalinputforAuto
mode
VFD-20 Speed B
Speed B
20) 35Hz
Min: PRIMARY-10
Max: PRIMARY-7
Default: 35.00Hz
Presetfrequency‐BbydigitalinputforAuto
mode
VFD-21 Speed AB
Speed AB
21) 40Hz
Min: PRIMARY-10
Max: PRIMARY-7
Default: 40.00Hz
Presetfrequency‐ABbytwodigitalinputsfor
Automode.
VFD-22 Preset Setpoint-A
Preset Setpoint-A
22)
Default: 50 PSI
PresetSet‐point‐AbydigitalinputforPIDmode.
VFD-23 Preset Setpoint-B
Preset Setpoint-B
23)
Default: 50 PSI
PresetSet‐point‐BbydigitalinputforPIDmode.
VFD-24 Preset Setpoint- AB
Preset Setpoint- AB
24)
Default: 60 PSI
PresetSet‐point‐ABbytwodigitalinputsforPID
mode
VFD-39 Reset User Settings
Reset User Settings
39) No
0 - No
1 - Factory Defaults
Default: (0) No
WhenFactoryDefaultsisselected,VFDwillload
factorydefaultsformotorandpowerline
parameters.
VFD-40 Custom Param 1
Custom Param 1
40) Output Frequency
0 - Output Frequency
1 - Motor Speed (RPM)
2 - Energy Usage
3 - Average Power
4 - Average Current
5 - Line A Current
6 - Line B Current
7 - Line C Current
8 - DC Bus Voltage
9 - Output Voltage
10 - HOA Mode
11 - IGBT Temp
12 - Ambient Temp
13 - Motor Run Time
14 - D1-SG Input
15 - D2-SG Input
16 - V1-V2 Input
17 - V3-V4 Input
18 - O1-O2 Output
19 - 1A mA Input
20 - 1A V Input
21 - 2A Input
22 - 2A mA Output
23 - 2A V Output
Default: 0 – Output
Frequency
CustomParameter1forConfigurabledisplay
VFD-41 Custom Param 2
Custom Param 2
41)
Speed
Selection options same
as VFD-40
Default: 1 - Motor
CustomParameter1forConfigurabledisplay
VFD-42 Custom Param 3
Custom Param 3
42)
Selection options same
as VFD-40
Default: 2 - Energy Use