72 Cyclone PRO User Manual
CYCLONE PRO
Figure 8-15: Power Down Dialog
3. Software automatically powers up the ICS, which configures the pro-
cessor’s MON08 configuration pins.
4. Software asks the user to power up the board as follows:
Figure 8-16: Power Up Dialog
Power Down ICS, Ask the user to power cycle their board, Power UP ICS
This option will work for many ICS boards as well, but relies on the fact that
while the ICS is powered off, it will hold the target in reset until it is powered
up itself and has configured the MON08 configuration pins. The sequence of
events in this mode is:
1. Software automatically powers down the ICS.
2. Software asks the user to power cycle their board as follows: