Parked HVAC Comfort Guide
Rest Hours Desired
Weather Setting Guide
Outdoor Temperature
Less Than or Equal
to: °F (°C)
Sunshine Less Than
or Equal to:
Maximum Blower
Speed
Minimum
Temperature Knob
Setting
12
90 (32) Night Time 6 10 O’clock
100 (38) Night Time 6 Mid
Table 8.1, Parked HVAC Comfort Guide
Temperature Control Knob Position to Requested
Output Temperature
Temperature Control
Knob Position (Clicks)
Requested Sleeper
Temperature: °F (°C)
1 60 (16)
2 60 (16)
3 62 (17)
4 64 (18)
5 66 (19)
6 68 (20)
7 70 (21)
8 71 (22)
9 72 (22)
10 73 (23)
11 74 (23)
12 75 (24)
13 76 (24)
14 77 (25)
15 78 (25)
16 79 (26)
17 80 (27)
18 82 (38)
19 84 (29)
20 85 (29)
21 Full Hot
Table 8.2, Temperature Control Knob Position to
Requested Output Temperature
Vehicles with Detroit Diesel Optimized
Idle
If a Cascadia vehicle is equipped with Detroit Diesel
optimized idle (O/I), it will affect the way the
ParkSmart operates. When the driver initiates the
O/I, the ParkSmart will operate in O/I mode as fol-
lows.
•
The ParkSmart runs unless the ParkSmart fan
speed control knob is turned to the "OFF" posi-
tion. See
Fig. 8.6. The fan speed control knob
must be set at "1" or higher.
•
The engine will periodically start and run for at
least two hours to maintain battery voltage
then shut off. The ParkSmart will continue to
operate during this time.
•
If the O/I shuts down due to a fault in the O/I
system, the ParkSmart will continue to operate
until it is shut off by the driver or one of the
automated failsafes.
•
The ParkSmart ON/OFF button and LED indi-
cator on the parked HVAC control module do
not function when the vehicle is in O/I mode.
When the vehicle is not in O/I mode, the
ParkSmart ON/OFF button and LED indicator
operate normally.
All other functions are the same as the standard sys-
tem.
Accessory Heaters
Optional accessary heaters are available from the
factory in several configurations. Familiarize yourself
with the equipment on your specific vehicle, and fol-
low the manufacturer’s operating and maintenance
instructions.
WARNING
Do not operate fuel-operated heaters in an area
where flammable vapors, including gasoline or
diesel fumes, are present, such as at filling sta-
tions and tank farms. Turn off a fuel-operated
heater and allow it shut down completely before
entering an area where flammable gases or liq-
uids are present. Heaters continue to operate for
up to three minutes after being turned off.
Climate Control
8.5