S90-010 M FRICK
QUANTUM™ COMPRESSOR CONTROL PANEL
Page 16 MAINTENANCE
DIGITAL I/O BOARD #1 PICTORIAL
TEST FUSE HERE.
IF LAMP LIGHTS
FUSE IS OK
SPARE FUSE
5A
F20
M20
INPUT MODULE
OPTIONAL
IN
IN
P5
5A
F19
M19
INPUT MODULE
OPTIONAL
IN
5A
F18
M18
INPUT MODULE
OPTIONAL
IN
5A
F17
M17
INPUT MODULE
OPTIONAL
IN
P4
5A
F13
M13
INPUT MODULE
IN
5A
OUT
F12
M12
OUTPUT MODULE
OPTIONAL
5A
OUT
F11
M11
OUTPUT MODULE
OPTIONAL
P3
5A
OUT
F10
M10
OUTPUT MODULE
OPTIONAL
5A
OUT
F9
M9
OUTPUT MODULE
OPTIONAL
5A
OUT
F8
M8
OUTPUT MODULE
5A
OUT
F7
M7
OUTPUT MODULE
P2
5A
OUT
F6
M6
OUTPUT MODULE
5A
OUT
F5
M5
OUTPUT MODULE
5A
F4
M4
INPUT MODULE
IN
5A
OUT
F3
M3
OUTPUT MODULE
P1
5A
F2
M2
INPUT MODULE
IN
INSTALLED
FUSE
OUTPUT MODULE
POWER
ON
FUSE POSITION DETERMINES
INPUT OR OUTPUT
IN = INPUT OR UPPER LOCATION
OUT = OUTPUT OR LOWER LOCATION
5A
OUT
F1
M1
OUTPUT MODULE
AMP794068-1
PROGRAM EPROM
DIO
19200
PROGRAM VERSION
I/O COMMUNICATION
ACTIVITY LAMPS
MICROPROCESSOR
WATCHDOG LAMP
(BLINKS IF OK)
5A
FUSE
SPARE
FUSE
FUSE TESTER
AMP794068-1
P6
5A
OUT
F24
M24
OUTPUT MODULE
OPTIONAL
1
DP1
J7
J8
J9
J10
5A
OUT
F16
M16
OUTPUT MODULE
OPTIONAL
5A
OUT
F15
M15
OUTPUT MODULE
OPTIONAL
5A
F14
M14
INPUT MODULE
IN
SERIAL #
REVISION
DIPSWITCH SETTINGS SIGNIFY
BOARD IDENTIFICATION NUMBER
COMMUNICATIONS JUMPERS
5A
OUT
F23
M23
OUTPUT MODULE
5A
OUT
F22
M22
OUTPUT MODULE
5A
OUT
F21
M21
OUTPUT MODULE
INPUT MODULE
COMPR. START/RUN 1
COMPR. AUX
HOT
NEUTRAL
OIL PUMP #1 1
START/RUN
OIL PUMP #1 AUX
SLIDE VALVE LOAD
SLIDE VALVE UNLOAD
HOT
NEUTRAL
SLIDE STOP INCREASE
SLIDE STOP DECREASE
LIQUID INJECTION 2
HI VI LIQUID INJECTION 2
HOT
NEUTRAL
ECONOMIZER 2,3
BALANCE PISTON 2,4
OIL LEVEL 5
HI LIQ. LEVEL FROM SYSTEM 6,9
HOT
NEUTRAL
ENCLOSURE HEATER 7
HOT GAS BYPASS 3
AUX. #1 10,6
AUX #2 10,6
NEUTRAL
PROCESS MODE SELECT 12
CAP. CONT. S.P. #2
OIL HEATER
ALARM 13
HOT
NEUTRAL
SHUTDOWN 14
POWER ASSIST 15
DIGITAL I/O BOARD #1
PART # 640D0062H01
REPLACEMENT PART # 640C0024G01
NOTE 1: 2 AMP LOAD
NOTE 2: IF REQUIRED
NOTE 3: PROGRAMMABLE SLIDE VALVE SETPOINT
NOTE 4: ON RWB’S 316 – 676
NOTE 5: NOT REQUIRED WITH
FULL LUBE OIL PUMP.
NOTE 6: SAFE CLOSED
NOTE 7: (OPTIONAL) AD 590 MTD ON BOARD
NOTE 8: PROGRAMMBABLE OPEN OR CLOSED
NOTE 9: JUMP 5 TO 25 IF NOT USED
NOTE 10: PROGRAMMABLE SHUTDOWN OR ALARM
NOTE 11: SETPOINT #2 WHEN CLOSED
NOTE 12: ALTERNATE MODE WHEN CLOSED
NOTE 13: ENERGIZE ON ALARM
NOTE 14: DE-ENERGIZE ON SHUTDOWN
NOTE 15: POWER ASSIST IS ADDED
AT TIME OF MANUFACTURE
+5 VOLTS
+12 VOLTS
-12 VOLTS
-RX / -TX
+RX / +TX
BOARD DC POWER
+5 DC
POWER
IS OK
U8
P7