FAQ | 5
B1820023_en | Service handbook Lambdatronic H 3200 - T4e 103
5.5.3 “Continuous load” mode without storage tank
When “Continuous load” is selected, the boiler produces heat around the clock, in other words it tries to
maintain its boiler temperature setpoint 24 hours a day. The boiler time settings are ignored in this mode.
The heating times and DHW tank loading times can be distributed throughout the day as required.
Example 1: “Continuous load” mode
Heating time 2
Heating time 1
setback mode
DHW tank loading time 1
DHW tank loading time 2
Tip: In systems with solar panels, choose the DHW tank loading time so that solar energy can be used.
Example 2: “Continuous load” mode with solar panel system
Heating time 2
Heating time 1
setback mode
DHW tank loading time 1
5.5.4 “Continuous load” mode with storage tank
To ensure efficient operation, set systems with a storage tank to “Automatic” mode rather than
“Continuous load” mode.
Ü "“Automatic” mode with storage tank" [}102]