2.3 Technical data
Description S3 Turbo 30 S3 Turbo 50
Nominal heat output kW
Btu/h
30
102,500
50
170,000
Electrical connection 230V / 60Hz / fused 15A
Power consumption at nominal load W
Btu/h
120
410
180
615
Weight of boiler incl. insulation and control kg
lbs
530
1170
620
1370
Total boiler capacity (water) l
gal
120
32
190
50
Minimum boiler return temperature °C
°F
60
140
Maximum permitted operating temperature 88
190
Permitted operating pressure bar
psi
2
30
Airborne sound level dB(A) < 70
Permitted fuel as per EN ISO 17225 Part 5: Firewood class A2 / D15 L50
Fuel loading door dimensions (width / height) mm
inches
330 / 370
13 / 14.5
330 / 370
13 / 14.5
Fuel loading chamber capacity l
gal
140
37
210
55
Combustion time
1)
– hardwood
h 3.9 - 5.6 3.9 - 5.6
Combustion time
1)
– soft wood
2.8 - 3.9 2.7 - 4.0
1.Values specified for combustion time are guideline values at nominal load and will vary depending on water content (15-25%) and fill level
(80-100%)
Technology
2
Technical data
Montageanleitung S3 Turbo | M1870119_en-us 33