EasyManuals Logo

Froling Turbomatic TMC 70 User Manual

Froling Turbomatic TMC 70
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
Technology
Technical specifications
Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestrasse 12, A-4710 Grieskirchen Page 13
Tel +43 (0) 7248 606-0 Fax +43 (0) 7248 606-600 info@froeling.com www.froeling.com
M1020008_en
2
Test data for operation with pellets
Description Unit 70 85 100
Testing institute BLT Wieselburg
Test report no.
Date of issue
1)
1)
1)
Carbon monoxide (CO)
Rated load
Partial load
mg/MJ
25.09
68.09
17.18
45.18
9.27
22.27
Nitrogen oxide (NOx)
Rated load
Partial load
mg/MJ
74.09
not measured
66.18
not measured
58.27
not measured
Organic hydrocarbons
Rated load
Partial load
mg/MJ
<1
<1
<1
<1
<1
<1
Dust
Rated load
Partial load
mg/MJ
10.27
not measured
7.55
not measured
4.82
not measured
Boiler efficiency rating
Rated load
Partial load
%
91.31
91.83
92.02
91.85
92.73
91.88
1) Values for boiler sizes 70 kW, 85 kW and 100 kW are interpolated (calculated as per EN 303-5)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Froling Turbomatic TMC 70 and is the answer not in the manual?

Froling Turbomatic TMC 70 Specifications

General IconGeneral
BrandFroling
ModelTurbomatic TMC 70
CategoryBoiler
LanguageEnglish

Related product manuals