108
Fronius Agilo
Outdoor 100.0-3
Input data
Output data
General data
Protection devices
MPP voltage range 460 - 820 V DC
Max. input voltage
(at 1000 W/m²/ -10 °C in an open circuit)
950 V DC
Max. input current 227.0 A
Max. short circuit current of the solar modules 340.5 A
Nominal output power (P
nom
) 100 kVA
Max. output power 100 kVA
Nominal grid voltage 3 ~ NPE 400 V / 230 V
Grid voltage tolerance +10 / -5 %
1)
Nominal output current (three-phase) 150.2 A
Nominal frequency 50 - 60 Hz
1)
Total harmonic distortion < 3 %
Power factor cos phi 1
0.8 - 1 ind./cap.
2)
Max. permitted mains impedance Z
max
at PCC
3)
52 mOHM
Max. feedback current
4)
0 A
5)
Starting current pulse
6)
0 A
5)
Max. output fault current per period 522 A / 2.47 ms
Maximum efficiency 97.2 %
Europ. efficiency 96.6 %
Overnight internal consumption 36 W
Cooling Controlled forced-air ventilation
Degree of protection IP 44
Dimensions l x w x h 1205 x 863 x 1914 mm
Weight 806 kg
Permitted ambient temperature
(4 - 100 % condensing)
- 25 °C - +50 °C
EMC emission class A
Overvoltage category AC / DC 3 / 2
Degree of pollution 3
DC insulation measurement Warning/shutdown
7)
at R
ISO
< 40 kOhm
Manifestation of DC overload Operating point shift
power limitation
DC circuit breaker Integrated