Meter calibration
Input of a correction value to ensure that the value shown on the inverter display corre-
sponds with the calibrated display on the electricity meter
DATCOM Checking data communications, entering the inverter number, protocol settings
Status
Indicates data communication is taking place via a Fronius Solar Net or that a data com-
munications error has occurred
Inverter number
Sets the number (= address) of the inverter in a system with several solar inverters
Protocol type
Specifies the communications protocol to be used to transfer the data:
Device Info For displaying the settings that will be of relevance to an energy supply company. The val-
ues shown will depend on the country setup or the device-specific settings of the inverter.
Setting range k / M
Factory setting -
Unit %
Setting range -5.0 - +5.0
Factory setting 0
Setting range Status / inverter number / protocol type
Unit -
Setting range 00 - 99 (00 = 100th inverter)
Factory setting 01
IMPORTANT! If a number of inverters are linked together in a data communications sys-
tem, assign a unique address to each one.
Unit -
Setting range Solar Net / Interface
Factory setting Solar Net
Display area General / MPP Tracker / Grid Monitoring / Voltage Limits / Fre-
quency Limits / P AC Reduction
General:
Setup Country setup
Version Version of country setup
Group Group for updating the inverter software
MPP Tracker: