64
Maintenance
Maintenance
personnel
WARNING!
Risk of injury and damage if maintenance work is not carried out cor-
rectly.
It is essential to adhere to the maintenance intervals and maintenance proce-
dures. The manufacturer accepts no liability for any damage caused by inad-
equate or poorly performed maintenance.
- All maintenance work on the welding carriage must be carried out by trained
technicians.
The following measures regarding maintenance must be put in place by the system
operator:
- a service book containing the required information (date, operator, maintenance work
carried out) must be kept.
Maintenance
record
Recommended
lubricants
IMPORTANT! Lubricants with solid lubricant additives (e.g.: MoS2, graphite and PTFE)
are not suitable for guiding systems.
Lubricant DIN DIN number Comment
Grease KP 2-K 51502 / 51825 Lithium soap grease
Lubricating oil CLP32-100 51517 Part 3 ISO VG 32-100
Electrically qualied person / technician:
Is a person who is able to evaluate the working steps, based on his specic technical
training, experiences and the well known relevant standards / regulations to recognize
possible risks / hazards.
Electrically instructed person:
Is a person who was trained by an electrically qualied person and was instructed
of the possible risks that can appear due to improper use / behaviour as well as the
necessary protective measures.
Notice: instruction has to be recorded
Electrically ordinary person:
Is a layperson who is neither an electrically qualied person nor a electrically instructed
person.