65
Item Component Procedure Interval
A
Linear guides Clean, check oil lm M
B
Gearbox Clean, regrease M
C
Rack and pinion Clean, regrease M
D
Rollers, underbody & rails Clean, check position M
E
Safety devices:
- Limit switch
Function test D
F
Grease nipples Regrease M
G
Connection contacts Cleaning W
D Daily
W Weekly
M Monthly
1/2 y Half-yearly
Y Yearly
Maintenance
intervals and
procedures
NOTE! Use a dry cleaning cloth to clean the machine components. Only
use a cleaning agent if this is indicated in the maintenance procedure for a
specic part.
G
G
C
E
Daily care:
After every use:
Remove the welding carriage from the guide rail.
Using a brush or a soft cloth, clean the guide rails for the oscillation unit, the guide
rollers and the gearbox.
Carry out maintenance work as shown in the illustration below.
IMPORTANT! Do not use compressed air.