9
Position the Minitek plug (2) in the
handle
NOTE!
Observe the following when positioning
the Minitek plug:
▶
Press the cable sheathing (6) right
down to the bottom of the strain-relief
device guide
▶
Lay the control line (7) in a loop
underneath the handle screw connec-
tion
10
Insert the coupling housing (1) and
close the hand grip as per the “Closing
the hand grip” chapter
Replacing the
coupling housing
Removal
1
Open the hand grip as per the “Open-
ing the hand grip” chapter
NOTE!
Carefully place the socket onto the con-
tact element to prevent damage.
2
Open the contact element (1) with the
8 mm socket
NOTE!
The coupling housing must be replaced
as a closed unit.
3
Remove the contact element (1)
4
Carefully remove the coupling housing
(2)
29