Fitting compon-
ents after
replacement
Mounting the central connector
(1)(2)
(4)
(3)
1
Insert the insert pieces (1)
2
Thread in control line (2)
Water-cooled version only:
3
Thread in water flow hose (3) and
water return hose (4)
(1)
(1)
(1)
(1)
4
Apply the cover
5
Screw in four TX 8 screws (1)
Tightening torque: 0.6 Nm
53