Electrical testing
of operating ele-
ments and dis-
plays
Inspection equipment: Test box “manual torch” (4,045,998)
Check the operating elements and displays for electrical function.
ATTENTION! ?
For proper testing, the lastest version of the service software for the test box
“manual torch” must be installed. It is available via the download center.
ATTENTION! ?
During the test, bend and twist the entire hosepack so that any interruptions in the
control line can be identified.
i-type manual torch:
(1)
(2)
(3)
(4)
1
Connect the test box manual torch (1)
to the test box FSC (2) as shown
2
Connect the adapter FSC - TMC (3) to
the test box FSC (2) (switch set to Up/
Down)
3
Connect the manual torch’s control
line (4) to the adapter FSC - TMC (3)
4
Make settings on the test box:
- Up/Down = LocalNet-devices
5
Check the operating elements are
working correctly for each interface
version
Example: Electrical test Up/Down as per PP-3188 test schedule:
a) Rocker switch left long, press forwards = LED final current
b) Rocker switch left long, press backwards = LED main current
c) Rocker switch right short, press forwards = LED down
d) Rocker switch right short, press backwards = LED up
e) Press the LED button = the LED button becomes active on the test box display