50
Fig.8 Unplugging connection between power source
and cooling unit
Loosen the Allen screws on the front
and back feet of the power source
Carefully lift power source and unplug
connection (G) between it and the co-
oling unit (Fig.8)
– Note! When lifting the power
source be careful not to strain the
cable connection between the po-
wer source and cooling unit.
Lift power source off cooling unit
(Fig.8)
Loosen the „Extrude-Tite“ screws on
the front and back feet of the cooling
unit
Fig.9 Trolley with auto-transformer
Lift cooling unit off trolley floor
Place auto-transformer onto trolley
floor (Fig.9)
Fasten the auto-transformer at the
front and back to the fastening bra-
ckets on the trolley floor using „Extru-
de-Tite“ screws (from cooling unit)
(Fig.9)
Fig.10 Inserting hexagon nuts
On the top of the auto-transformer, in-
sert the hexagon nuts provided into the
hexagon-shaped openings (I) on the fi-
xing bars (as with cooling unit; see
Fig.10)
Fig.11 Trolley with auto-transformer and cooling unit
Carefully place cooling unit onto auto-
transformer (Fig.11)
Firmly attach cooling unit to the auto-
transformer at the front and back using
the Allen screws provided (4) (Fig.11)
(G)
Power source
Cooling unit
(I)
Cooling unit
Auto-transformer