72
CAUTION!
Risk of injury due to an electric shock
Although Fronius devices comply with all relevant standards, the high frequency ignition
can transmit a harmless but noticeable electric shock under certain circumstances.
► Use prescribed protective clothing, especially gloves!
► Only use suitable, completely intact and undamaged TIG hosepacks!
► Do not work in damp or wet environments!
► Take special care when working on scaffolds, work platforms, in forced positions, in
tight, difficult to access or exposed places!
Pulse TAC display
off / on
Factory setting: on
This menu item can be used to hide the pulsing and tacking parameters on the control pan-
el in the welding parameter overview.
Ignition time out
Period of time until the safety cut-out following failed ignition
0.1 - 9.9 s
Factory setting: 5 s
Arc break monitoring
Period of time until the safety cut-out following an arc break
0.1 - 9.9 s
Factory setting: 1.0 s
IMPORTANT! Arc break monitoring is a safety function and cannot be deactivated.
A description of the arc break monitoring function can be found in the "TIG Welding" sec-
tion on page 61.
TIG Comfort Stop sensibility - comfort stop sensitivity
The parameter is only available if the "Trigger" parameter is set to "off".
oFF / 0.6 - 3.5 V
Factory setting: 1.5 V
At the end of the welding process, an automatic shutdown of the welding current follows a
significant increase of the arc length. This prevents the arc from having to be unnecessarily
lengthened when lifting the TIG welding torch.