14-5
14.1 Crossover Racks
14
Disassembly
1. Remove the dryer entrance rack.
2. Remove the seven E-rings and cap from the rear of the dryer entrance rack then the seven gears, eight bearings
and four coil springs.
3. Remove the eight E-rings from the front of the rack then the eight bearings and four coil springs.
4. Remove the four E-rings from the rear of the rack and then the four idler gears.
5. Remove the eight rollers.
Reassembly
Reassembly is essentially in the reverse order of
disassembly.
NOTE: Install the black marked coil springs to the lower
roller bearings as shown.
14.1.3 Dryer Entrance Rack Disassembly/Reassembly
LII575
E-rings (8)
Gears (7)
Bearings (8)
Coil Springs (4)
Bearings (8)
Coil Springs (4)
E-rings (7)
E-rings (4)
Idler Gears (4)
Rollers (8)
Cap
LII576
Black Mark