Power Distribution Unit
There are two sizes for power distribution units: 1U and 2U.
A power distribution unit is an option to connect power supply units to power outlets when power sockets are
limited.
■
Power Distribution Unit (AC8A/200V, 1U, 4 Outlets)
There are four outlets and two inlets.
Figure 173 Power Distribution Unit (AC8A/200V, 1U, 4 Outlets)
1 Main line switch
This turns on and off the power distribution unit.
2 Outlet (OUTPUT)
This is a socket (IEC60320 C13) for outgoing power supply. This socket is used to connect a power cord (AC
output cable).
3 Inlet (INPUT)
This is a socket (IEC60320 C14) for incoming power supply. This socket is used to connect a power cord (AC
input cable).
The specifications of a power distribution unit and the power cords that are provided are shown below.
Table 95 Power Distribution Unit (AC8A/200V, 1U, 4 Outlets) and Provided Power Cord Specifications
Item Specifications
Power Voltage AC 200 – 240V
Phase Single
Frequency 50Hz/60Hz
Input cable Connection type
IEC60320 C13 n NEMA L6-15P
Length 3m
Quantity 2
6. Hardware Configurations
Power Distribution Unit
275 Design Guide