Chapter 3 Information About Software 25
RTIF1-
070418-020
O O When using the XSCF Web to import a
firmware image, if the image is
corrupted (for example, if the browser
window is closed during import), the
flashupdate command might later
report an internal error.
CR ID 6537996 is similar.
Use the command getflashimage
-d to delete the corrupted image. If
necessary, reboot the XSCF Unit, then
use the flashupdate command
again to clear the internal error.
RTIF1-
070418-021
O O Attempting to move a COD board
using the moveboard(8) command
might fail.
Use the deleteboard(8) and
addboard(8) commands instead of
the moveboard(8) command.
RTIF1-
070418-022
O O The XSCF firmware monitors itself
and if it detects any abnormalities, it
will force a reset.
Allow the XSCF Unit to finish
resetting. It will return to normal
operation within approximately 5
minutes.
RTIF1-
070418-023
OOUsing the rebootxscf(8) command
may result in a process down error,
and possibly an FMA event with MSG
ID SCF-8005-NE.
Ignore this event.
RTIF1-
070418-025
OOshowaudit all shows a long list of
defaults in the policy section after the
database is cleared.
Update the database with the
following:
setaudit -a opl=enable
setaudit -a opl=default
RTIF1-
070528-001
O O When you have updated the
/etc/ttydefs file of Oracle Solaris
OS to disable the console flow control,
you cannot disable the console flow
control on the telnet via a server.
No workaround is available.
TABLE 3-3 XCP Issues Fixed in Releases Earlier Than XCP 1121 (Continued)
ID M3000
M4000
M5000
M8000
M9000 Description Workaround