Chapter 3 Information About Software 27
RTIF1-
070824-001
OOOM8000/M9000 servers:
When remote power control mode of
interlocking mechanism for power
supply to domain, is enabled, after
XSCF Unit is replaced, the
interlocking for power supply by RCI
cannot work.
M3000/M4000/M5000 servers:
When remote power control mode of
interlocking mechanism for power
supply to domain, is enabled, after the
motherboard unit is replaced, the
interlocking for power supply by RCI
cannot work.
M8000/M9000 servers:
After XSCF Unit is replaced,
configures the RCI again and sets the
remote power control mode.
M3000/M4000/M5000 servers:
After the motherboard unit is
replaced, configures the RCI again
and sets the remote power control
mode.
RTIF1-
070824-002
O O On the XSCF Web, when you select
Domain Mode Configuration to
perform various settings, the pop-up
screen may not appear but
"Undefined" may be displayed on
the screen.
Select Domain Mode Configuration
one more time and perform the
settings. Or once terminate the XSCF
Web and then perform the settings.
RTIF1-
070824-003
O O On the XSCF Web, while the XCP
import is in process from the
[Firmware Update] screen, when you
execute the [REFRESH] button, the
pop-up of "Uploading Now!"
disappears and the XCP import
terminates abnormally.
None available at this time.
RTIF1-
070824-004
O O On the XSCF Web, on the [Domain
Status] screen, when you select an
XSB displayed on the Domain
Component List, and in case the
selected XSB is not yet mounted or is
Uni-XSB, the pop-up screen displays
no data.
None available at this time.
RTIF1-
070824-005
O O On the XSCF Web, when you changed
the Refresh Interval value of the
Monitor Message Frame, the invalid
pop-up "Confirmation Domain
mode" may appear.
Ignore the pop-up and close the
screen.
TABLE 3-3 XCP Issues Fixed in Releases Earlier Than XCP 1121 (Continued)
ID M3000
M4000
M5000
M8000
M9000 Description Workaround