50 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1121 February 2016
RTIF1-
111227-001
O O In case of connecting an External I/O
Expansion Unit, a message
"watchdog timeout" might be
registered in an error log under the
following conditions:
•Executes the switchscf(8)
command on an M8000/M9000
server.
•Executes the rebootxscf(8)
command on an M4000/M5000
server.
No workaround is available.
RTIF1-
120216-001
O O Using PCI hot-plug, when you
perform active addition of a PCI card
or perform active maintenance or
active addition of an external I/O
expansion unit, operation may fail.
Stop the target domain before the
addition of a PCI card or before the
maintenance or addition of an
external I/O expansion unit.
RTIF1-
120319-001
OOOAn internal module of the fmd
process (case-close module) turns
disable.
If you continue the operation in a
situation that the case-close module is
disabled, an fmd process failure
occurs and resets XSCF.
No workaround is available.
RTIF1-
120322-001
OOOWhile starting the XSCF, SSH service
might be disabled and cannot perform
SSH connection.
Wait for the XSCF finish starting, and
then retry SSH connection. If SSH
service has been disabled, reset the
XSCF using the rebootxscf(8)
command.
RTIF1-
120326-001
OOOExecuting the setldap -p command
with a password that contains a colon
(:) causes a problem with the LDAP
configuration.
No workaround is available.
To recover, execute
restoreconfig(8) to restore the last
working LDAP configuration.
RTIF1-
120329-004
OOOWhen the XSCF unit is monitored by
Ops Center, the service processor can
sometimes reset or failover
unexpectedly.
Disable Ops Center monitoring of the
XSCF unit.
RTIF1-
120424-001
O There is a low probability that FRU
replacement, which is performed by
the replacefru(8) command, fails
during the replacement of XSCF
boards in reaction to an XSCF board
failure.
No workaround is available.
TABLE 3-3 XCP Issues Fixed in Releases Earlier Than XCP 1121 (Continued)