80 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1121 February 2016
6496337 O O The "cpumem-diagnosis" module may
fail to load after uncorrectable
error(UE) panic.
Systems will function correctly but
events normally automatically
diagnosed by FMA using this module
will require manual diagnosis.
Example:
SUNW-MSG-ID: FMD-8000-2K,
TYPE: Defect, VER: 1,
SEVERITY: Minor
EVENT-TIME: Thu Feb 15
15:46:57 JST 2007
PLATFORM: SUNW,SPARC-
Enterprise, CSN: BE80601007,
HOSTNAME: col2-ff-em7-d0
For Oracle Solaris 10 11/06, this has
been fixed in patch 125369-05.
[Workaround]
If problem occurred, implement the
following
workaround:
1. Remove the following file.
# rm /var/fm/fmd/ckpt/cpumem-
diagnosis/cpumem-diagnosis
1. Restart fmd service.
# svcadm restart fmd
To avoid this problem in advance,
add "rm -f
/var/fm/fmd/ckpt/cpumem-
diagnosis/cpumem-diagnosis" in
/lib/svc/method/svc-dumpadm
file as below.
#
# We haven't run savecore on
a dump device yet
#
savedev=none
rm -f
/var/fm/fmd/ckpt/cpumem-
diagnosis/cpumem-diagnosis
#
6498283 O O Using the DR deleteboard(8)
command while psradm operations
are running on a domain might cause
a system panic.
For Oracle Solaris 10 11/06, this has
been fixed in patch 120011-07.
[Workaround]
No workaround is available.
TABLE 3-11 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 8/07 (Continued)
CR ID M3000
M4000
M5000
M8000
M9000 Description Workaround