Doc No:
006614
Revision:
D
Date:
14/08/2020
Page 10 of 58
o 115/230 V AC
Features related to the software:
o Adjustable times for each cleaning phase
o Automatic selection of chemicals for pre-determined wash cycle
o Manually step through the cleaning cycle to check the cleaning process
o Manually start a specific cleaning phase
o Automatic disinfection can be performed before milking
o Recording of cleaning parameters and errors occurred during cleaning process
o Internal diagnostics to test the PCB
6.2. The FullClean Plus Operational Modes
The FullClean Plus user interface software is divided into two parts:
6.2.1. Operation Mode
This mode is the normal function mode of the controller. The keys on the terminal allow the
user to start or stop the milking and the cleaning, view the cleaning status, confirm warnings,
and change some user settings, for instance the start time of the automatic disinfection before
milking. More information about this mode is provided in Section 10; User operation.
6.2.2. Adjust Mode
This mode is used by a technician to set all technical settings of the controller. This mode is
protected by an on-board dipswitch setting. More information about this mode is provided in
Section 12; Technical operation.
6.3. The FullClean Plus Cleaning Possibilities
The firmware mentioned above, for the FullClean Plus controller, supports two types of
cleaning.
6.3.1. Circulation Cleaning
This cleaning procedure is based on washing the milking equipment in three or four phases
where basically cleaning water with detergent is circulated through the system for a certain
period.
6.3.2. Heat Based Cleaning
This is a simple cleaning procedure, based on washing the equipment with boiling water which
runs through the system only once.
In Section 9: hardware installation and wiring of the FullClean Plus controller, information is
provided according to the type of cleaning desired.