EasyManua.ls Logo

Fullwood Packo FullClean Plus - Options and Settings of the Circulation Based Cleaning System

Fullwood Packo FullClean Plus
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Doc No:
006614
Revision:
D
Date:
14/08/2020
Page 45 of 58
12.1.6. Options and Settings of the Circulation Based Cleaning System
The following tables detail the options and settings of the Circulation Based Cleaning System.
Main Menu
item
Sub Menu items
Range
Default
User
General
Language
EN / CZ / P
EN
Cleaning system
None / heat based /
Circulation
None
Perform full reset
No / Yes
No
Disinfection
Water inlet
Cold water, Hot water,
Cold & hot water, Water
storage, Hot water
storage, None.
Cold
water
Cold water fill time
mm:ss 0:00-10:00
10:00
Chemical disp. delay
mm:ss 0:00-10:00
0:00
Chemical amount
mm:ss 0:00-10:00
0:00
Max. filling time
mm:ss 0:00-59:59
10:00
Water outlet
Water spray unit, Water-
storage, Drinking trough,
Waste.
Water
spray
unit
Drain time
mm:ss 0:00-59:59
2:00
Milk Meter start delay
mm:ss 0:00-10:00
0:05
Milk Meter on-time
mm:ss 0:00-10:00
0:25
Milk Meter off-time
mm:ss 0:00-10:00
2:30
ACR start delay
mm:ss 0:00-10:00
0:00
ACR on-time
mm:ss 0:00-10:00
0:00
ACR off-time
mm:ss 0:00-10:00
0:00
Air inj. start delay
mm:ss 0:00-10:00
0:30
Air inj. on-time
mm:ss 0:00-10:00
0:07
Air inj. off-time
mm:ss 0:00-10:00
0:13
Pulsator start delay
mm:ss 0:00-10:00
0:00
Pulsator on-time
mm:ss 0:00-10:00
0:00
Pulsator off-time
mm:ss 0:00-10:00
0:00
Dry time
mm:ss 0:00-10:00
1:00
Vessel drain time
mm:ss 0:00-10:00
0:20
Compr. Air inlet time
mm:ss 0:00-10:00
0:00
Pre-rinse
Vacuum pump
On, Off
On

Table of Contents