Loading...
Doc No:
006614
Revision:
D
Date:
14/08/2020
Page 46 of 58
Main Menu
item
Sub Menu items
Range
Default
User
Pre-rinse
(continued)
Water inlet
Cold & hot water, Water
storage, Hot water
storage, None, Cold
water, Hot water.
Cold &
hot water
Cold water fill time
mm:ss 0:00-10:00
2:30
Max. filling time
mm:ss 0:00-59:59
10:00
Water outlet
Waste, Water spray unit,
Water storage, Drinking
trough.
Waste
Drain time
mm:ss 0:00-59:59
2:00
Milk pump start delay
mm:ss 0:00-10:00
0:00
Milk pump on-time
mm:ss 0:00-10:00
0:00
Milk Meter start delay
mm:ss 0:00-10:00
0:02
Milk Meter on-time
mm:ss 0:00-10:00
0:25
Milk Meter off-time
mm:ss 0:00-10:00
2:30
ACR start delay
mm:ss 0:00-10:00
0:00
ACR on-time
mm:ss 0:00-10:00
0:00
ACR off-time
mm:ss 0:00-10:00
0:00
Air inj. start delay
mm:ss 0:00-10:00
0:05
Air inj. on-time
mm:ss 0:00-10:00
0:07
Air inj. off-time
mm:ss 0:00-10:00
0:13
Pulsator start delay
mm:ss 0:00-10:00
0:00
Pulsator on-time
mm:ss 0:00-10:00
0:00
Pulsator off-time
mm:ss 0:00-10:00
0:00
Dry time
mm:ss 0:00-10:00
0:15
Vessel drain time
mm:ss 0:00-10:00
0:15
Compr. Air inlet time
mm:ss 0:00-10:00
0:00
Hot Wash
Vacuum pump
Off, On
Off
Chemical disp. delay
mm:ss 0:00-10:00
0:00
Chemical amount
mm:ss 0:00-10:00
0:00
Alt. chemical amount
mm:ss 0:00-10:00
0:00
Max. filling time
mm:ss 0:00-59:59
10:00
Max. water dump time
mm:ss 0:00-10:00
0:00
Circulation #1 time
mm:ss 0:00-59:59
0:00
Min. circ. Temp.
0…99 ºC
40

Table of Contents