NOTE
The number of available main menu items depend on the cleaning system as
set in “general” > “cleaning system”. If no cleaning system (“none” = factory
default) has been set, only the main menu item “general” is available.
Be careful with the menu item “perform full reset”, it will erase all settings and
restore the factory defaults!
The first time the FullClean Plus controller is started-up, and no general settings have been
made yet, only the Main Menu item “General” is available. In that case these general settings
need to be made first.
The following menu items are always available in General (see also Figure 22):
• Language (Select the desired language with + or - and activate with enter)
• Cleaning system (Select circulation or heat based with + or - and activate with enter)
• Perform full reset (Warning! The memory will be erased, all settings will be lost if set
to Yes!)
The keys at the front of the controller have the following functions in Adjust Mode:
• – Go to next Main Menu item (top level scrolling).
Press repeatedly to scroll through the available Main
Menu items
• – Enter the sub menu of the current menu item.
Press repeatedly to scroll through the available sub menu
items
If the “Heat based” cleaning system has been set, the following Main Menu items are available:
• General
• Pre-rinse
• Hot wash
• Drain & dry
• Hot water reservoir
• Hardware input assignments
• Hardware valves
• Hardware equipment
If the “Circulation” cleaning system has been set, the following Main Menu items are available:
• General
• Disinfection
• Pre-rinse
• Hot wash
• Final rinse
• 2nd After-rinse