Doc No:
006614
Revision:
D
Date:
14/08/2020
Page 41 of 58
Main Menu
item
Sub Menu items
Range
Default
User
Hot wash
(continued)
Air inj. start delay
mm:ss 0:00-10:00
0:25
Air inj. on-time
mm:ss 0:00-10:00
0:07
Air inj. off-time
mm:ss 0:00-10:00
0:13
Pulsator start delay
mm:ss 0:00-10:00
0:00
Pulsator on-time
mm:ss 0:00-10:00
0:00
Pulsator off-time
mm:ss 0:00-10:00
0:00
Water outlet
Waste, Water spray unit,
Water storage, Drinking
trough.
Water
storage
Drain time
mm:ss 0:00-59:59
5:00
Dry time
mm:ss 0:00-10:00
0:35
Vessel drain time
mm:ss 0:00-10:00
0:20
Comp. air inlet time
mm:ss 0:00-10:00
0:00
Drain & dry
Drain time
mm:ss 0:00-59:59
2:00
Vessel drain time
mm:ss 0:00-10:00
0:20
Comp. air inlet time
mm:ss 0:00-10:00
0:00
Hot water
reservoir
Heating vessel level X Y
X= input # (0-64); Y:
Neither, On-board, 4-
IN/OUT, 16-IN
2 Neither
Heating vessel temp X Y
X= input # (0-64); Y:
Neither, On-board, 4-
IN/OUT, 16-IN
3 Neither
Heating vessel inlet X Y
X= input # (0-64); Y:
Neither, On-board, 4-
IN/OUT, 16-OUT
0 Neither
Heating vessel elem. X Y
X= input # (0-64); Y:
Neither, On-board, 4-
IN/OUT, 16-OUT
0 Neither
Hardware
input
assignments
Delivery line X Y
X= input # (0-64); Y:
Neither, On-board, 4-
IN/OUT, 16-IN
1 On-
board
Wash trough lo level X Y
X= input # (0-64); Y:
Neither, On-board, 4-
IN/OUT, 16-IN
2 Neither
Wash trough hi level X Y
X= input # (0-64); Y:
Neither, On-board, 4-
IN/OUT, 16-IN
3 Neither
Chemical I level X Y
X= input # (0-64); Y:
Neither, On-board, 4-
IN/OUT, 16-IN
0 Neither

Table of Contents