Main Menu
item
Sub Menu items
Range
Default
User
Final rinse
(continued)
Water outlet
Water spray unit, Water
storage, Drinking trough,
Waste.
Water
spray
unit
Drain time
mm:ss 0:00-59:59
2:00
Milk Meter start delay
mm:ss 0:00-10:00
0:05
Milk Meter on-time
mm:ss 0:00-10:00
0:25
Milk Meter off-time
mm:ss 0:00-10:00
2:30
ACR start delay
mm:ss 0:00-10:00
0:00
ACR on-time
mm:ss 0:00-10:00
0:00
ACR off-time
mm:ss 0:00-10:00
0:00
Air inj. start delay
mm:ss 0:00-10:00
0:30
Air inj. on-time
mm:ss 0:00-10:00
0:07
Air inj. off-time
mm:ss 0:00-10:00
0:13
Pulsator start delay
mm:ss 0:00-10:00
0:00
Pulsator on-time
mm:ss 0:00-10:00
0:00
Pulsator off-time
mm:ss 0:00-10:00
0:00
Dry time
mm:ss 0:00-10:00
1:00
Vessel drain time
mm:ss 0:00-10:00
0:20
Compr. air inlet time
mm:ss 0:00-10:00
0:00
2nd After-
rinse
Vacuum pump
Off, On
Off
Water inlet
Cold water, Hot water,
Cold & hot water, Water
storage, Hot water
storage, None.
Cold
water
Cold water fill time
mm:ss 0:00-10:00
10:00
Chemical disp. delay
mm:ss 0:00-10:00
0:00
Chemical amount
mm:ss 0:00-10:00
0:00
Chemical type
None, Chemical #1,
Chemical #2, Chemical
#3.
None
Max. filling time
mm:ss 0:00-59:59
10:00
Water outlet
Water spray unit, Water
storage, Drinking trough,
Waste.
Water
spray
unit
Drain time
mm:ss 0:00-59:59
2:00
Milk Meter start delay
mm:ss 0:00-10:00
0:05

Table of Contents