Description Comments
A Boiler serial number UniquenumbergiventoeachFultonboilerforidentication
B Product model Name of product
C Product group Type of product
D Year of manufacture Year that the product was made (not year boiler was sold or commissioned)
E Boiler steam output Amount of steam (kg/h) the boiler is capable of producing if the feedwater
entering the boiler is 100 °C
F CE marking European Conformity - mandatory conformity marking for certain products
sold/manufactured within the European Economic Area
G Supply voltage Electrical supply requirements for the boiler
H Design temperature The temperature used in the design calculations
K Design pressure The pressure used in the design calculations
L Safety valve set pressure Pre-setliftpressureofthettedsafetyvalve(settopreventboilersteam
overload)
M Maximum allowable
pressure
Maximum safe pressure the boiler has been designed to operate at
N Test pressure The pressure the boiler was tested to during hydraulic testing
P Date of test This is the date of the hydraulic testing
Q Max continuous rating Energy input of the boiler
R Manufactured by Company that manufactured the product
S Design standard British standard (BS) used to design and manufacture the product
T  AnotiedbodyisanentitythathasbeenaccreditedbyaMemberState
to assess whether a product to be placed on the market meets certain
preordained standards