6. OTHER FUNCTIONS
6-6
Services:
Alphabet shown only when Flag is “1” for a bit.
Bit No. Flag Meaning Display
1 Maritime distress alerting A 1B8
0 No Maritime distress alerting None
1 SafetyNET traffic S 1B7
0 No SafetyNET traffic None
1 Inmarsat-C traffic C 1B6
0 No Inmarsat-C traffic None
1 Store and Forward T 1B5
0 No Store and Forward None
1 Half Duplex H 1B4
0 No Half Duplex None
1 Full Duplex D 1B3
0 No Full Duplex None
1 Closed Network N 1B2
0 No Closed Network None
1 FleetNET Traffic F 1B1
0 No FleetNET Traffic None
1 Prefixed store and forward message supported P 2B8
0 Prefixed store and forward message not supported None
1 Land mobile alerting 2B7
0 No Land mobile alerting
1 Aero-C service supported 2B6
0 Aero-C service not supported
Not used
1 ITA2 transmission supported I 2B5
0 ITA2 transmission not supported None
1 Data transmission supported B 2B4
0 Data transmission not supported None
1 Basic X.400 supported X 2B3
0 Basic X.400 not supported None
1 Enhanced X.400 supported E 2B2
0 Enhanced X.400 not supported None
1 Low power C MES supported L 2B1
0 Low power C MES not supported None
TDM Ch.: TDM channel used by LES to transmit.

Table of Contents

Other manuals for Furuno FELCOM 16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FELCOM 16 and is the answer not in the manual?

Furuno FELCOM 16 Specifications

General IconGeneral
BrandFuruno
ModelFELCOM 16
CategorySecurity System
LanguageEnglish

Related product manuals