FusionServer 2288H V5 Server
Technical White Paper
5 Hardware Description
Issue 11 (2023-04-30)
Copyright © xFusion Digital Technologies Co., Ltd.
21
Indicator
Description
Blinking green at 4 Hz: The firmware is being
upgraded online.
Steady green: The power input and output are normal.
Steady orange: The input is normal, but no power
output is supplied.
NOTE
The possible causes of no power output are as follows:
Power supply overtemperature protection
Power output overcurrent or short-circuit
Output overvoltage
Short-circuit protection
Device failure (excluding failure of all devices)
UID Indicator
The UID indicator helps identify and locate a device.
Off: The device is not being located.
Blinking or steady blue: The device is being located.
NOTE
You can turn on or off the UID indicator by pressing the UID
button or remotely running a command on the iBMC CLI.
Data transmission
status indicator of the
management network
port
Off: No data is being transmitted.
Blinking yellow: Data is being transmitted.
Connection status
indicator of the
management network
port
Off: The network port is not connected.
Steady green: The network port is properly connected.