44
Specification
Relay Output*:
Max
1 Relay per Analog Channel
Output Type
Potential Free Contact, 1 From C
Configuration
High/Low/High-Low/On-Off (Hysteresis band
settable)
Life expectancy
Mechanical:10
7
Operations
Electrical :10
5
Operations
Load
1A ,230V AC resistive
Relay Refresh Rate
1 Sec.
Isolation Relay-Relay
2.5KV 1Minute
Isolation Relay Contact - GND
1.5KV 1Minute
Safety
EMI-EMC
IEC 61326-1 Class A
Safety
IEC 61010-1
Pollution Degree
II
Installation Category
III
Vibration
2g Peak (10Hz – 150Hz)
Shock
IEC61010-1
IP Rating
IP50(Door and Bezel Only)
Overall Dimension
Dimension L x W x D (mm)
411X376X130
Panel Cutout (mm) (L x W)
319X323
Bezel (mm)
411X376