8 TECHNICAL DATA
8.1 CHARGING STATION TECHNICAL DATA
Product type GARO Entity Pro
Standards IEC 61851-1
IEC 62955
IEC 61439-7
EN 60898-1
EN 61008-1
EMC classification 2014/30/EU
Installation method Wall in a single and/or double installation bracket.
(Stand and pole mount fixtures are available as
accessories)
Installation environment Indoor/outdoor
Location type Non-restricted access
Rated voltage TN 2-3 phase 400 VAC 50 Hz
TN 1 phase 230 VAC 50 Hz
IT/TT 2-3 phase 230 VAC 50 Hz
Rated current 32 A or 20 A depending on fixed cable version. The
default setting is always 16 A. The maximum installed
current for the charging station (CS) is set by the Installer.
Installation systems TN, IT and TT systems
Charging type Type 2/Mode 3
Charging method AC charging
Protection class IP54
Mechanical impact resistance IK10
Temperature range -40 °C - +40 °C. Charging current is reduced at higher
temperatures.