13
The output can drive a single 8-ohm speaker or multiple speaker circuit of 8-ohms or higher (as
shown in the following speaker wiring diagrams). Compatible speakers are described under
“Connecting Piezo Sirens”.
To avoid disabling the panel speaker output, do not make speaker connections with the
panel powered up.
15-Watt Speaker (13-060)
For exterior siren applications. Connect the speaker to the panel as shown in Figure 13.
Hardwire Interior Speaker (60-528)
For interior siren applications. Connect the speaker to the panel as shown in Figure 14.
Connect only the large speaker to the panel terminals 7 and 8 as shown. The smaller
speaker cannot handle to output of terminals 7 and 8. To avoid damaging the speaker,
the smaller speaker should not be connected to terminals 7 and 8.
Connect two units to the panel terminals with speakers in series (16-ohms), as shown in Figure
15.
Figure 15. Connecting Two Hardwire Interior Speakers w/Dual Speaker Units to Panel Terminals
Splice
S
pea
k
er
S
pea
k
er
2 8-Ohm Speakers in
Series (16 Ohms)
Figure 13. Connecting Speakers to the Panel
87
Speaker
Not Used
Panel
Terminals
Figure 14. Connecting the Hardwire Interior
Speaker with Dual Speakers to the Panel
Not Used
Not Used
Speaker
Terminals
Panel
Caution
!